Pump is destined for re-pumping sludge or for internal re-circulation of sludge in sewage treatment plants. Pump is designed for pumping stuffs at small delivery heads. When selecting a pump, the customer is requested to specify his requirements for its parameters thoroughly. This pump is intended for operation outdoors. A pumped liquid:
Temperature of a pumped liquid up to 40 °C
Max.density of a pumped liquid 1,050 kg/m3
Value pH according to a material option 4 – 8.5
Simple construction with a bearing being lubricated by a pumped stuff. It has been modified for installation into vertical pipeline (by welding or with the aid of a flange joint) or on a free water surface. Shape of the propeller blades and arrangement of this pump internal space are destined to pump liquids with fibrous admixtures. Drive is provided by means of a vertical flanged electric motor with reinforced lower bearing
Pumps are manufactured according to the customer wish in steel or all-stainless versions.
Operation of this pump does not need continuous attendance and its maintenance is described in the Operation Instructions.
| Type | PKC-H-200-K | PKC-H-150-K | PKC-H-100-K | PKC-H-70-K |
| PKC-H-200-N | PKC-H-150-N | PKC-H-100-N | PKC-H-70-N | |
| Q [l . s-1] | 4-15 | 0-2 | ||
| H [m] | 0,7–0,3 | 0,45-0,2 | ||
| P [kW] | 1,1 | 0,75 | 0,75 (0,55) | 0,55 (0,37) |
| n [min-1] | 680 | 915 | 1395 | 1395 |
| Material options | K – steel | K – steel | K – steel | K - steel |
| N - stainless steel | N - stainless steel | N - stainless steel | N - stainless steel | |
| A1 [mm] | 205 | 150 | 94 | 64 |
| A2 [mm] | 205 | 150 | 94 | 94 |
| B [mm] | 260 | 237 | 160 | 160 |
| C [mm] | 900 | 900 | 740 | 740 |
| D [mm] | 250 | 230 | 152 | 150 |
| E [mm] | 312 | 281 | 232 | 232/210 |
| E1 [mm] | 363 | 333 | 261,5 | 261,5/239 |
| Fmin [mm] | 200 | 200 | 120 | 120 |